Lenovo 6532 User Manual

Page 97

Advertising
background image

Table 5. DSA Preboot messages (continued)

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is

solved.

• See Chapter 7 “Parts listing, RS210 Types 6531, 6532, 6533, and 6534” on page 175 to determine which

components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

• If an action step is preceded by “(Trained service technician only),” that step must be performed only by

a Trained service technician.

• Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information,

hints, tips, and new device drivers or to submit a request for information.

Message
number

Component Test

State

Description

Action

201-810-xxx Memory

Memory
Test

Aborted Test

stopped:
unknown
error
code xxx
received in
COMMONEXIT
procedure.

1. Turn off and restart the system.

2. Run the test again.

3. Make sure that the DSA code is at the latest

level. For the latest level of DSA code, go to
http://www.lenovo.com/support.

4. Make sure that the server firmware is at

the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this component. For
more information, see “Updating the firmware”
on page 211
.

5. Run the test again.

6. If the failure remains, go to the Lenovo Web site

for more troubleshooting information at
http://www.lenovo.com/support..

201-901-xxx Memory

Memory
Test

Failed

Test failure:
single-bit
error, failing
DIMM z.

1. Turn off the system and disconnect it from the

power source.

2. Reseat DIMM z.

3. Reconnect the system to power and turn on

the system.

4. Make sure that the DSA code is at the latest

level. For the latest level of DSA code, go to
http://www.lenovo.com/support.

5. Make sure that the server firmware is at

the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this component. For
more information, see “Updating the firmware”
on page 211
.

6. Run the test again.

7. Replace the failing DIMMs.

8. Re-enable all memory in the Setup utility (see

“Using the Setup Utility” on page 197).

9. Run the test again.

10. Replace the failing DIMM.

11. If the failure remains, go to the Lenovo Web site

for more troubleshooting information at
http://www.lenovo.com/support..

Chapter 4

.

Diagnostics

89