• Follow the suggested actions in the order in which they are listed in the Action column until the problem is

solved.

• See Chapter 7 “Parts listing, RS210 Types 6531, 6532, 6533, and 6534” on page 175 to determine which

components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

• If an action step is preceded by “(Trained service technician only),” that step must be performed only by

a trained service technician.

ENET[0] DHCP-HSTN=%1,
DN=%2, IP@=%3, SN=%4,
GW@=%5, DNS1@=%6.(%1 =
CIM_DNSProtocolEndpoint.Hostname;
%2 =
CIM_DNSProtocolEndpoint.DomainName;
%3 =
CIM_IPProtocolEndpoint.IPv4Address;
%4 =
CIM_IPProtocolEndpoint.SubnetMask;
%5 = IP address, xxx.xxx.xxx.xxx; %6
= IP address, xxx.xxx.xxx.xxx)

Info

The DHCP server has
assigned an IMM IP address
and configuration.

No action; information only.

ENET[0] IP-Cfg:HstName=%1,
IP@%2, NetMsk=%3,
GW@=%4.(%1 =
CIM_DNSProtocolEndpoint.Hostname;
%2 =
CIM_StaticIPSettingData.IPv4Address;
%3 =
CIM_StaticIPSettingData.SubnetMask;
%4 =
CIM_StaticIPSettingData.DefaultGatewayAddress)

Info

An IMM IP address and
configuration have been
assigned using client data.

No action; information only.

LAN: Ethernet[0] interface is no longer
active.

Info

The IMM Ethernet interface
has been disabled.

No action; information only.

LAN: Ethernet[0] interface is now
active.

Info

The IMM Ethernet interface
has been enabled.

No action; information only.

DHCP setting changed to by user
%1.(%1 = user ID)

Info

A user has changed the
DHCP mode.

No action; information only.

IMM: Configuration %1 restored from
a configuration file by user %2.(%1 =
CIM_ConfigurationData.ConfigurationName;
%2 = user ID)

Info

A user has restored the IMM
configuration by importing a
configuration file.

No action; information only.

Watchdog %1 Screen Capture
Occurred.(%1 = OS Watchdog or
Loader Watchdog)

Error

An operating-system error
has occurred, and the screen
capture was successful.

1. Reconfigure the watchdog

timer to a higher value.

2. Make sure that the IMM

Ethernet over USB interface is
enabled.

3. Reinstall the RNDIS or

cdc_ether device driver for the
operating system.

4. Disable the watchdog.

5. Check the integrity of the

installed operating system.

Chapter 4

.

Diagnostics

43