NEC UNIVERGE NEAX 2000 IPS User Manual

Page 141

Advertising
background image

Chapter 8 System Administration

UNIVERGE

NEAX

2000 IPS

Request for Proposal (RFP) Reference Guide

Page 8- 3

Issue 6

The method you use depends on how you installed and configured the device to which you
want to connect. A serial cable direct connection offers better performance than a modem
connection, but requires that the PC and device be within 50 feet of each other. A TCP/IP
connection offers excellent performance and flexibility but requires a network connection to
both your PC and the device.

PBX Configuration Wizard

The PBX Configuration Wizard is a custom tool in MATWorX that enables you to establish the proper
communication settings between your computer and the

U

NIVERGE

NEAX

2000 IPS. The Wizard asks

you simple questions and then uses the information to automatically configure the connection for the
PC and the PBX.

Service Conditions

1. Connection through modems is available, providing remote maintenance capabilities.

2. MATWorX can be connected to the system either directly or remotely. Direct connection is through

the RS connector on the MP card. Remote connection is available via either an internal modem on
the MP card or an external modem for high speed. Remote connection via the internal modem is
through the COT card. Connection between the modem and the COT is accomplished through
internal switching of the TDSW. Remote connection via an external modem is through the MP card.

3. The following functions can be performed from MATWorX:

System, station, and trunk data entry, change, and copy.

Loading, saving, and verification of system data to and from a disk.

ROM check readout of generic program.

Display of fault/fault cleared messages.

On-site or remote access to the system.

Printout of system data (when printer is connected to PC).

Display and setting of system clock/calendar.

Numbering Plan

Least Cost Routing (LCR)

System initialize

UCD/Station Hunting/Call Pickup – Group

4. The PC used with MATWorX must have an RS-232C port, and cannot be located more than 50 feet

(15m) from the system when connected on premises.

5. When stations or trunks are expanded, moved, or changed, office data for a Multiline Terminal

key/station/ trunk can be copied and multiple assignments of related office data is possible.

MACH Script Editor

This is a powerful timesaving tool that enables you to create a list of

U

NIVERGE

NEAX

2000 IPS

commands that perform tasks in the PBX. This list is referred to as a script, which can be saved and
run at anytime. You can also use the MACH Script Editor to perform many other operations.