NEC UNIVERGE NEAX 2000 IPS User Manual

Page 254

Advertising
background image

Chapter 13 Voice Over IP (VoIP)

Page 13- 12

UNIVERGE

NEAX

2000 IPS

Request for Proposal (RFP) Reference Guide

Issue 6

7. Because the IP station can have only two-operation mode (Location number), when the number of

remote sites (Location numbers) is over two, there is a case that the appropriate communications
may not be available. Refer to Example 2 for details.

Location number in each operation mode for each IP station:

<IP stations in Location #0: STA. 200 and 201>
Remote Connection Mode: Location #1
Local Connection Mode: Location #0
<IP stations in Location #1: STA. 202 and 302>
Remote Connection Mode: Location #1
Local Connection Mode: Location #0 or #2
<IP stations in Location #2: STA. 300 and 301>
Remote Connection Mode: Location #1
Local Connection Mode: Location #2

Operation mode for each IP terminal:

<IP terminals in Location #0>
Local Connection Mode
<IP terminals in Location #1>
Remote Connection Mode
<IP terminals in Location #2>
Local Connection Mode

Example 1: When Sta. 200 logs in Location #1

STA. 200 logs out from Location #0, and then logs in from IP terminals in Location #1. STA 200 works
in Remote Connection Mode (because IP terminals in Location # 1 are assigned to Remote Connection
Mode.), under the conditions of Location #1 (because STA. 200 in Remote Connection Mode is
assigned to operate under the condition of Location #1.). In this case, the appropriate communication is
available because the operating condition of STA. 200 matches the actual Location number (Location
#1).

Example 2: When Sta. 200 logs in Location #2

STA. 200 logs out from Location #0, and then logs in from IP terminals in Location #2. STA. 200 works
in Local Connection Mode (because IP terminals in Location # 2 are assigned to Locale Connection
Mode.), under the conditions of Location #0 (because STA. 200 in Local Connection Mode is assigned
to operate under the condition of Location #0.). In this case, the appropriate communication may not be
available because the operating condition of STA. 200 (Location #0) does not match the actual
Location number (Location #2).

8. Following features are not available for IP terminals at remote sites:

Multiple Line Operation

Assignment of feature keys which the lamp indication and ringer is controlled by other IP
terminals

Advertising