Chapter 3 System Highlights

UNIVERGE

NEAX

2000 IPS

Request For Proposal (RFP) Reference Guide

Page 3-17

Issue 6

Transmission Characteristics (For TDM Circuits)

Description

Specifications

PCM Coding System

A-law/U-law

Insertion Loss

0.15 dB at 1KHz

Return Loss

20 dB or more (300 to 3,400Hz) against 600 ohms

Longitudinal Balance

59 dB or more (300 to 3,400Hz)

Attenuation/Frequency Distortion

-0.2 dB to +0.7 dB (300 to 3,400Hz)

Group Delay Distortion

0 to 0.3msec. (500 to 2,800 Hz)

Total Distortion

25 dB (Input signal:-45 dBm0)/40 dB(input signal:0 dBm0)

Idle Channel Noise

-67 dBmop or less (psophometric noise)
-50 dBm0 or less (single frequency noise)

Impulsive Noise

0 counts at -35 dBm

Cross Talk Attenuation

90 dB or more

Inter-modulation Products

-40 dB or more

Spurious In-Band Signals

-49 dBm0 or less

Signal Attenuation

Attenuation rate: 12 dB per octave or more at 3.4 kHz above
Attenuation level: -40 dBm or less at 3.4 kHz and above
-70 dBm or less at 50 kHz and above

Line Conditions

Description

Specifications

Loop Resistance (including Telephone Set)
Analog Standard Line

Max. 600 ohms

Analog Long Line

Max. 2,500 ohms (DP 10pps), Max. 1,700 ohms (DP 20pps)
Max. 1,200 ohms (DTMF)

Loop Resistance (including Opposite End Resistance)
Central Office Trunk

Max. 1,700 ohms

Tie Line Trunk (Loop Dial)

Max. 2,500 ohms

Tie Line Trunk (E&M)

Max. 900 ohms (only E-wire condition)

Cable Length Note 1
SN716 Desk Console

8DLC/4DLC/2DLC Card

Max. 350 meters (Max. 300 meters for 8DLC card)

4DLC/2DLC Card with
AC Adapter

Max. 1,200 meters

Dterm Series i/E

8DLC/4DLC Card

Max. 200 meters (Max. 300 meters for Dterm 8 and Dterm 8D)

2DLC Card

Max. 850 meters

4DLC/2DLC Card with
AC Adapter

Max. 1,200 meters

DSS/BLF Console

4DLC/2DLC Card with
AC Adapter

Max. 1,200 meters

Zone Transceiver

ZTII-U (for U-Interface)

Max. 1,210 meters (2-wire), Max. 2,100 meters (4-wire) @-48V

Max. 970 meters (2-wire), Max. 1,700 meters (4-wire) @-45V

ZTII-U with AC Adapter

Max. 3,950 meters

Note 1:

Cable length is based on cable with 0.5mm diameter and without lightning arresters