Wireless specifications – NEC UNIVERGE NEAX 2000 IPS User Manual

Page 337

Advertising
background image

Chapter 16 Wireless System


UNIVERGE

NEAX

2000 IPS Request For Proposal (RFP) Reference Guide Page 16-15

Issue 6

Wireless Specifications

Zone Transceiver II Specifications

ITEM

SPECIFICATIONS

• ZT II U
Output Power

6.8 mW

Type of Interface

U Interface

Number of Simultaneous Speech Path

Maximum 3

Power Supply

• PBX Power Supply (DC –48 V)
• Local Power Supply (AC 100 V/200 V)

Power Consumption

Maximum 3 W

Operating Conditions

Ambient Temperature: –10 50 °C
Relative Humidity : 45 - 85 % (non-condensing)
Installation Location : Indoor

Dimensions (unit: mm)

160 (W) x139 (D) x40 (H) (Excluding Antenna)

Weight Approx.

400

g

Wire Diameter

26 AWG

24 AWG

22 AWG

19AWG

2W

2500 ft.

(762 m)

4000 ft.

(1219 m)

5500 ft.

(1676 m)

8000 ft.

(2438 m)

PBX Power
Supply at -48 V

4W

4300 ft.

(1310 m)

6900 ft.

(2103 m)

9500 ft.

(2895 m)

13000 ft.

(3958 m)

2W

2000 ft.

(609 m)

3200 ft.

(975 m)

4700 ft.

(1432 m)

7000 ft.

(2131 m)

PBX Power
Supply at -45 V

4W

3500 ft.

(1066 m)

5600 ft.

(1706 m)

8200 ft.

(2499 m)

12200 ft.

(3718 m)

2W

1800 ft.

(548 m)

2900 ft.

(883 m)

4400 ft.

(1340 m)

6400 ft.

(1948 m)

PBX Power
Supply at -43 V

4W

3100 ft.

(944 m)

5000ft.

(1524 m)

7600 ft.

(2316 m)

11000 ft.

(3352 m)

Local Power Supply

11000 ft.

(3350 m)

13000 ft.

(3958 m)

13000 ft.

(3958 m)

13000 ft.

(3958 m)

System Capacity

Capacity

Integrated

Adjunct (Analog)

Adjunct (CCIS)

Description

1PIM

2PIM 3PIM 4PIM 5PIM 6PIM 7PIM 8PIM

Zone

Transceiver

(ZT)

16 32 48 64 80 96 112 128

Dterm PS

Note

512

CSI 4CSIA-A

32

CSH

24

PS Simultaneous Connections

216

Calling Area

32

ZT per Calling Area

128

Note:

All existing CSH cards in a system should be SPN-SC03B 8CSH-C (AP) when accommodating

257 or more PSs.

Advertising