H.323 Features

The following service features are available when connecting with H.323 terminal (NEC product). For
other vender products, confirmation test is required.

H.323 Features

Call Forwarding-All Calls

Speed Calling-Station

Call Forwarding-Don’t Answer

Bearer Service

Call Forwarding-Busy Line

Tandem Switching of TIE Trunks-2/4-Wire

Split Call Forwarding

The Line Connection with PAD Control

Call Transfer-All Calls

Outgoing Trunk Busy Announcement

Hotline

Brokerage Hot Line-Outside

Do not Disturb-Dterm

Least Cost Routing-3/6-Digit

Calling/Called Number Display

LCR-Time of Day Routing

Digital Display-Trunk

Attendant Manual Override

Speed Calling-System

Echo Canceller Control

Service Conditions for H.323

1. The data network used for H.323 must be a corporate Intranet.
2. Gatekeeper is required for H.323 network.
3. IP trunk cards must be connected with a corporate Intranet via a router.
4. CCIS feature key FD is required.
5. Maximum number of nodes in the network depends on the capability of the Gatekeeper.
6. Maximum one IP trunk card can be accommodated per PIM and maximum eight IP trunk cards per

system.

7. Maximum voice channels per IP trunk card depends on the payload period as follows (payload

period can be assigned in system programming):

Maximum Voice Channels per IP Trunk

Payload Period

G.729a

G.711

G.723.1

20

ms 6 5 –

30

ms 8 7 8

40 ms

12

10

Note:

Maximum 96 channels can be provided per system

8. The same IP trunk card cannot be shared with CCIS network via IP and H.323.
9. Tone signals to an extension are provided by the system.
10. When a LAN cable is unplugged from the IP trunk card, the associated calls are disconnected.
11. When connected with the system by other manufacturer, a pre-connection test is required.
12. DTMF Relay is supported.