System specifications – NEC UNIVERGE NEAX 2000 IPS User Manual

Page 64

Advertising
background image

Chapter 3 System Highlights

Page 3- 16

UNIVERGE

NEAX

2000 IPS

Request For Proposal (RFP) Reference Guide

Issue 6

System Specifications

AC Power Requirements

Description

Specifications

AC Input Voltage

90 to 132Vac or 180 to 264Vac; 47 to 64Hz

AC Input Current

3.5A(at 100V), 2.0A(at 200V)

AC Power Consumption / Thermal Output (Maximum)

AC Power Consumption (KVA)

Thermal Output (BTU)

Description

100V

200V

100V

200V

1-PIM 0.35

0.40

1,195

1,365

2-PIM 0.70

0.80

2,389

2,730

3-PIM 1.05

1.20

3,584

4,096

4-PIM 1.40

1.60

4,778

5,461

5-PIM 1.75

2.00

5,973

6,826

6-PIM 2.10

2.40

7,167

8,191

7-PIM 2.45

2.80

8,362

9,556

8-PIM 2.80

3.20

9,556

10,922

Battery Requirements

Description

Specifications

Max. Battery Capacity

260AH per 4 PIM (65AH (12V) x 8)

DC Input Voltage for Battery

-24V

Built-in Battery Requirements

3.4AH (12V) x 2 (approx. 30min. backup)

Physical Size of Built-in Battery
(one 12V battery)

133(W) x 60(H) x 67(D) mm

Operating Environment

Description

Specifications

Ambient Temperature

0° to 40° Celsius

Relative Humidity

Max. 90% (non-condensing)

Electrical Characteristics (Central Office Trunk)

Description

Specifications

Insulation Resistance

15 mega-ohms or more at 100Vdc

DC Resistance

On-hook conditions: 30 mega-ohms
Off-hook conditions: 1,700 ohms

Impedance

On-hook conditions: 20 kilo-ohms (300 to 3,400Hz)
8 kilo-ohms (at 24Hz)
Looped conditions: 600 ohms

Leak Current

0 mA at on-hook conditions

Advertising