Chapter 12 Automatic Call Distribution with MIS

Page 12- 8

UNIVERGE

NEAX

2000 IPS

Request for Proposal (RFP) Reference Guide

Issue 6

Business System Capacities

Capacities

Item ACD

CallCenterWorX

ACD 3.0

CallCenterWorX

MIS 3.0

Tenants per System

9

Splits per ACD Tenant

Note 1

Note 1

Splits per System

150

150

Splits per Logon ID

32

32

Active ACD Agents per
System

120 Note 2/ Note 4

120 Note 2

Trunks per System

255 Note 4

255

Maximum Queue Depth

300

Priority Levels 1

250

Note 3

Maximum Calls in
Queue per System

300 –

Transfer to PBX
Numbers

120 –

Agent Logon ID Codes
per System

400 400

Agent Logon ID Code
Digits

9 9

Statistics Report History
Limit

1.5GB

MIS per System

8

8

Pilot Numbers

300 Note 4 300

Tally Code Names per
Split

– 100

Tally Code Names per
System

– 3000

Busy Hour Call Attempts
(BHCA)

Note 5

Note 1

:

The total number of splits per system (150) is shared among the total number of tenants (up to 9).

Note 2: Agent positions available depend on the installed security key’s capacity for logged-on agents. The
total number of agents is shared among the total number of tenants (up to 9). Security keys are available in
the following capacities: 10, 20, 30, 40, 60, 80, 100, & 120.

Note 3: The MIS tracks Split queue calls as “High” and “Standard.”

Note 4: Dependent upon the CallCenterWorX configuration formula based on the OAI monitoring limitations:
(Agents x 2) + (Pilots and/or Personal Pilots) + Trunks + IVR Ports must be equal to or less than 256.


Note 5:

BHCA (Busy Hour Call Attempts)

Number of PIM’s

1PIM

2PIM

3PIM

4PIM

5PIM

6PIM

7PIM

8PIM

Business or
Hotel/Motel
with ACD/OAI

Max. 2000 BHCA
(No FP)


Max. 4000 BHCA
(One FP)


Max. 5000 BHCA
(Two FPs)


Max. 5500 BHCA
(Three FPs)