Chapter 2 System Architecture

Page 2- 8

UNIVERGE

NEAX

2000 IPS

Request For Proposal (RFP) Reference Guide

Issue 6

Cabling

The internal and external cabling for the

U

NIVERGE

NEAX

2000 IPS is as follows:

Internal Cabling

BUS Cable

The BUS Cable provides a connection between PIM’s for I/O Bus, PCM Bus, and Alarm Bus extension
in a multiple-PIM configuration.

Bus Cable

Name Code

Qty

Remarks

48-TW-0.7 CONN CA

(No. of PIM)-1 0.7 m (2.3ft.)

Power Control Cable

The Power Control Cable provides a connection between the MP and the AC/DC Power Supply for
controlling battery backup function and MJ/MN alarm indication.

Power Control Cable

Name Code

Qty

Remarks

PWR CNT CA-D

1/PIM

Power control cable (for PIMI-PIM7):
BWB - PZ-PW121/122 (Included in
PIM)

PWR CNT CA-E

1/PIM

Power control cable (for PIM0)
BWB - PZ-PW121/122 (Included in
Base and PIM for Dual System)


DC Power Cable

The DC Power Cable provides a connection between the AC/DC Power Supplies for extending the 27
VDC input in a multiple-PIM configuration, when battery backup option is required

.

Power Cable (Internal Battery Option)

Name Code

Qty

Remarks

PWR CA-A

1/2 PIM

DC Power Cable (-27v input)

BATT CA INT

1/PIM

Internal Battery Cable

Power Cable (External Battery Option)

Name Code

Qty

Remarks

PWR CA-A

(No. of PIM) –1= up to 4PIM
(No. of PIM) –2= 5 to 8PIM

DC Power Cable (-27v input)

BATT CA EXT

1/Stack

External Battery Cable

AC Cord

The AC cord provides a connection between the AC/DC Power Card and Base Unit.

AC Cord

Name Code

Qty

Remarks

AC CORD-B-U

1/PIM

AC power cable (Included in PIM)

AC CORD-D-U

1/BASE AC power cable for BASE (Included in BASE)