Chapter 2 System Architecture

Page 2- 14

UNIVERGE

NEAX

2000 IPS

Request For Proposal (RFP) Reference Guide

Issue 6

System Power Supply and Cooling Fan

AC/DC Power Supply


The AC/DC Power Card is mounted in the rear side of each MODULAR CHASSIS. The AC/DC Power
card provides power to all circuit cards, which are resided in the MODULAR CHASSIS.

AC power requirements are as follows:

Input Voltage: 85 to 264VAC, 50/60 Hz (Auto sensing 100V/200V selection)

AC/DC Power Card

Description

Qty

Remarks

PZ-PW131

1 per MODULAR CHASSIS

AC/DC Power Supply
Output:+5 V, 5.5A, -27 V, 3A


Back-up Power


UPS or battery backup (with external battery) is available for backup power for AC power failure. In
case of battery backup, sealed type battery should be used. The open type battery is not available
because of AC/DC power specifications.

Required Battery Capacity

Battery Backup Time

Required Battery Capacity

10 minutes (Built-in battery)

12VDC, 0.8AH x 2

30 minutes (External battery)

12VDC, 2.2AH x 2

3 hours (External battery)

12VDC, 12AH x 2

Ring Generator Unit (RGU)


The RGU provides ringing supply to analog SLT (PN-4LCAA is no longer required); however, it cannot
ring more than 6 analog SLT’s per MODULAR CHASSIS simultaneously. Therefore, the simultaneous
ringing has to be limited by office data setting.

Ring Generator Unit (RGU) Card

Description

Qty

Remarks

PZ-PW139 MODULAR

CHASSIS

Ring Generator Unit
Ring Voltage: 85/75Vac
Ring Current: 0.05A

Cooling FAN


The cooling FAN is mounted at the right side of each MODULAR CHASSIS. The FAN should be
replaced every 4 years in order to ensure the cooling system.

Cooling FAN

Description

Qty

Remarks

109P0624H
7D09 FAN

1 per MODULAR CHASSIS

Each Modular Chassis is equipped with a
Cooling Fan this part is for replacement only