NEC UNIVERGE NEAX 2000 IPS User Manual

Page 55

Advertising
background image

Chapter 3 System Highlights

UNIVERGE

NEAX

2000 IPS

Request For Proposal (RFP) Reference Guide

Page 3-7

Issue 6

Mean Time To Repair (MTTR)

The Mean Time To Repair has been studied with the following conditions:
1. A mid to high-level technical person will attend to the site for the detection of the fault and

replacement of the faulty circuit board.

2. All critical circuit boards for replacement are stocked at each Fault Dispatch Center (FDC).
3. All non-critical circuit boards for FDCs are stocked at NEC. The calculation result of the MTTR is

1.0 hour.

Reliability Calculations

The following information is to show you how to calculate the reliability for the system you are
configuring. Remember that these calculations are used to determine a partial system outage.

Reliability Calculation


1Defect

1FIT 10

9

1FIT=

MTBF=

=

1,000,000,000Hours•Parts

Total FITS Total FITS

System Calculation


To calculate the MTBF of a single system, obtain the sum of the FITs from each component.
For example: Assume you have a complete system that consists of two components:
Item A FIT=31,700, Item B FIT=80,000

Total Fit = 31,700 + 80,000 = 111,700


10

9

MTBF= = 8952.55 Hours

111,700

8,952.22

Hours

= 1.02 Years

8,760Hours / Year

Availability Calculations

MTBF

Availability=

MTBF+MTTR

=.9XXXXX