Power Supply setup

Configuring the serial (RS232) link

POWER ON RETAIN

Description

YES

When power is turned on, the XMP 2600 uses the
stored settings to automatically re-program all the
power modules to their last settings (a retain
operation).

NO

When power is turned on the XMP 2600 initializes
the parameters of all the power modules:





Vset=0, Iset=Imin, OUT=off

PROT = auto, HIGH=off, LOW=off

RIPL=off, LIM=max

SYNC=output settle

TRIG=arm values step

The global output enable flag is also cleared.

Configuring the serial (RS232) link

The RS232 serial communication link is used for either remotely controlling the
XMP 2600 power supply system or getting a full screen remote activity monitor.

Activating the

RS232 link

Activation of the RS232 serial communication link is done with the dip switches
located at the back of the XMP’s master mainframe but it can also be, temporarily,
activated using the front panel.

What is displayed

The following illustration shows the way the RS232 serial communication link is
activated (or disabled):

system

symbol

system

parameters to set

condensed

modules status

Serial activation

selection

Setup mode display – serial link activation

How to, temporarily, activate (or disable) the RS232

To control the state of the RS232 serial link proceed as follows:


Make sure the display is in setup mode.
Move the cursor (using the LEFT / RIGHT selection keys) to the SER
parameter.

XMP 2600 User’s Guide

rev. 1.0

81