Nter desired output current limit, Xit programming mode, Step 2: turn the power module on – Xantrex Technology XMP 2600 User Manual

Page 59: Elect a power module, Tart from status mode, Elect the power module to program, Nter programming mode, Urn the module on or off, Enter desired output current limit, Exit programming mode

Advertising
background image

Step 2: turn the power module on

First operation steps

Enter desired output current limit

Using the numeric entry keys, enter the desired value for the output current limit.

Exit

programming

mode

Press the

SET

key to exit programming mode. The cursor returns to the lower row

of the display and the upper row shows SET values (in status mode).

If you wish to turn the module on or off, do not exit the
programming mode and read the step 2 paragraph.

Step 2: turn the power module on

In step 1 you have programmed the desired output voltage and current limit. Now
you need to turn the module on, enabling its output.

If the display is already in module programming mode, skip to the paragraph on how
to actually turn the module ON or OFF.

Select a

power

module

Otherwise, you’ll need to select the power module you wish to turn on. Follow the
steps below to do that.

Start from status mode

Before you can select the desired power module you need the display to be in status
mode.

Use the guidelines presented in step 1 in order to go to status mode.

Select the power module to program

Now you can select the power module to be programmed using one of the following
methods:

Moving the cursor .......... Use the left and right selection (arrow) keys ←

→ to move the cursor to the condensed status

symbol of the desired power module.

Jumping to channel......... press the

CH

key and in the entry field that

opens at the lower row of the display, enter
(using the numeric entry keys) a two digits
module address or a single digit address followed
by the

ENTER

key.

Enter

programming

mode

Press the

SET

key to enter programming mode. The blinking black rectangle is now

replaced with a blinking carrot (“^”) and the cursor is moved to the upper row of the
display where it appears as an underline (“_”) under the voltage value.

The step 1 section (program output voltage and current), above, has a
comprehensive description of what is shown on the LCD display.

Turn the

module on or

off

Press the

OUT

key to change the state of the power module’s output to ON or OFF.

You can verify the state of the power module’s output by looking at it’s condensed
status symbol (at the display’s lower row, where the blinking carrot is):

40

XMP 2600 User’s Guide

rev. 1.0

Advertising