System parameters

Power Supply setup

How to select a value

Use the UP / DOWN selection keys to select the desired behavior for the buzzer, as
detailed in the table below.

BUZZER will sound

Description

NEVER

The audible alarm is disabled.

ON FAULTS

The audible alarm will sound when a fault or
warning event occurs. To silence the alarm, press
any key.

ALWAYS

The audible alarm will sound when a fault or
warning event occurs. To silence the alarm, press
any key.

A short beep will be heard when an illegal key is
pressed or erroneous value entry is made.

Setting the

power-on

retain

behavior

The power-on retain function controls whether the XMP 2600 power supply system
will remember its last settings when power is cycled.

In addition to the ten storage areas at the users disposal, the XMP 2600 has a storage
area dedicated to keeping the current settings of all the power modules and the state
of the global output enable. The power-on retain mechanism uses that storage area.

How to get there

Use the LEFT / RIGHT selection keys to move the cursor to the ON parameter.

What is displayed

The upper row of the display shows the selected state of the power-on retain
function.

Power-on retain

selection

condensed

modules status

system

parameters to set

system

symbol

Setup mode display – power-on retain selection

How to select a value

Use the UP / DOWN selection keys to select a value for the power on retain
function: