Viewing status information, Odules condensed status, Modules condensed status – Xantrex Technology XMP 2600 User Manual

Page 46

Advertising
background image

Using the front panel

Viewing status information

Operating mode

Cursor location

Function

Status mode

Any

Toggle the global enable state of
the outputs (as depicted by the
ON indicator)

All other modes

Any

Globally disable all the outputs (if
enabled)

Keeping any key pressed for more than a second invokes repeat of
the key function, at a rate of 10 times in a second.

Viewing status information

The following paragraphs detail the information shown on the LCD display in the
two status display modes: system status and module status.

Modules

condensed

status

The left part of the lower row of the LCD display contains 16 symbols that represent
the 16 available channels (module addresses) of the XMP 2600 mainframe. The
captions on the front panel indicate the channel number associated with the symbol
on the display.

Channels 10 to 16 are marked with the letters A to G.

Each of the above mentioned symbols is a condensed status display for the power
module installed in the associated channel (having the indicated address: 1 to 16).

The illustration below shows an example of power modules condensed status
display.

Portion of the display showing condensed modules status

The meaning of each displayed symbol is summarized in the table below.

Condensed

status symbol

Meaning of symbol

Channel is free – no power module is installed with that address.

Power module is OK with its output turned off.

Power module is OK with its output turned on.

Power module is OK with its output disconnect relay open.

Power module has a fault (e.g. OVP, OCP etc.).

Power module is malfunctioning (e.g. it does not respond to
communications from the main controller).

When a warning or fault event occurs, the condensed status symbol
blinks until the module is selected for detailed status viewing (see
below).

XMP 2600 User’s Guide

rev. 1.0

27