Using the front panel

Viewing status information

Severity

Displayed data

Description

Warnings

m wv wc t ERR nnn

m..............operating mode:







blank ...voltage mode
M.........current mode
F ..........foldback

wv ............window voltage warning:

blank ...no warning
LV .......low voltage
HV.......high voltage

wc ............window current warning:

blank ...no warning
LC .......low current
HC.......high current

t ................over temperature
ERR nnn..error with error code nnn

Faults

s fault t ERR nnn

s................open sense lines:





blank ...no fault
mode ...operating mode (see above)
S..........open sense fault

fault.........fault indication:

blank ...no fault
warn ....window warning (see

above)

*OVP* over voltage protection
*OCP* over current protection

t ................over temperature
ERR nnn

error with error code nnn

More information on the power modules and their setup is available
in the setup operating mode chapter. Please refer to the power
supply setup chapter for more information.