Running the sequence program

Sequence programming

Exit

sequence

program

editing mode

Press the SET key to exit sequence program editing mode and return the Power
Supply to status mode.

Running the sequence program

Activate the

sequence

program

To activate the sequence program proceed as follows:

Move the cursor to the system symbol (“Σ”) and make sure the power
supply is displaying global system status. Use the table below as a
guide on how to get there.

IF…

Take the action…

Operating in programming

mode (an underline cursor

is visible at the upper row

of the display)

Press the

SET

key to exit programming

mode and press the

SYSTEM

key to move

the cursor to the system symbol.

The cursor is not at the

system symbol (“Σ”)

Method 1: Press the

SYSTEM

key to move

the cursor to the system symbol.

Method 2: if the cursor (blinking black

rectangle) is at the lower row of
the display you can use the
selection keys ← → to move
the cursor to the system symbol.

The cursor is at the system

symbol but the upper row

shows other information.

Press the

SYSTEM

key, examine the

information on the upper row of the display
and act accordingly.

The cursor is at the system

symbol but the upper row
reads: “Power Supply Set

Up”

Press the

SET

key to exit the setup mode

and return to status mode.

You are unable to get the

display you want using the

instructions above.

Reset the power supply:

Method 1: Press and hold the

DEL

key and

then press

LOCAL

- the two

keys must be pressed together.

Method 2: recycle power using the line

switch.


Press the RCL key to initiate sequence program run mode.
A confirmation message is displayed: “PRESS ENTER TO START
PROGRAM”.

o Press ENTER to start execution of the sequence program.
o Press any other key to abort.