Power module setup, Hat is displayed, Ow to get there – Xantrex Technology XMP 2600 User Manual

Page 105: Isplay details, What is displayed, How to get there, Display details

Advertising
background image

Power module setup

Power Supply setup

Remember to set the LSN address to same value as the TLK address
by selecting it and pressing the ENTER key.

To end the GPIB setup mode, do one of the following:


Press the SET key.
Press the SYSTEM key. This will, also, move the cursor to the system
symbol.

Following power-on or a full reset the GPIB address and activation
state are restored from the dip switches located at the back of the
unit. For further details please refer to chapter 2: Installation.

Power module setup

In the setup mode you have access to additional power module parameters and
information.

What is

displayed

The following illustration shows a typical display of a power module setup.

Power module
location

Last known
error code

system

symbol

system

parameters to set

condensed

modules status

Power module

rating

Reprogramming

delay

Setup mode display – power module setup

How to get

there

To get to the power module setup proceed as follows:


Make sure the display is in setup mode.
Select the power module (move the cursor to the condensed status
symbol of the power module) using the LEFT / RIGHT selection keys.

Display

details

The information shown on the display during power module setup is summarized in
the table bellow:

Parameter

Description

MAX

Power module rating: maximal available output voltage and
current.

DLY=

The amount of reprogramming delay (shown in units of 0.1
second). To understand what reprogramming delay is, please
refer to the section on setting the reprogramming delay.

86

XMP 2600 User’s Guide

rev. 1.0