Viewing status information

Using the front panel

Viewing

module

status

When the front panel of the XMP 2600 operates in status mode and the cursor
(blinking black rectangle) is placed over the condensed status symbol of a power
module the upper row of the display shows detailed status information for the
selected power module.

What is displayed

When operating in module status mode, the upper row of the display shows diverse
information on the condition and setup of the selected power module.

The left part of the display’s upper row shows output or parameters values while the
right side, for the most part, shows power module status.


Parameter

value

operating

mode

foldback
selection

system

symbol

system status

or instructions

condensed

modules status

module status

Display showing module’s load values

By default, the display shows output values (voltage, current, operating mode and
current limit selection) – either LOAD values (measured using the sense lines) or
OUT values (measured at the output connector).

Other information may be selected for viewing using the UP and DOWN selection
(arrow) keys. The format of the displayed information may change according to the
parameter being selected for viewing (see “display details”, later on).

How to get there

To view detailed power module status, the display must be operating in status view
mode and the cursor must be placed over the condensed status symbol of the desired
power module.

Use the table below to get the display into the proper mode.

IF…

Take the action…

The cursor is at the system

symbol and the upper row shows

system status information.

OR

The display shows status

information for another power

module.

Select the desired power module:

Method 1: . Use the left and right selection

(arrow) keys ← → to move
the cursor to the condensed status
symbol of the desired power
module.

Method 2: press the

CH

key and in the

entry field that opens at the lower
row of the display, enter (using
the numeric entry keys) a two
digits module address or a single
digit address followed by the

ENTER

key.

30

XMP 2600 User’s Guide