Appendix c: test results, Byte 1, Byte 2 – Xantrex Technology XMP 2600 User Manual

Page 116: Test results

Advertising
background image

Test results

Power module setup

APPENDIX

C

Test results

The Power Module Test or Confidence Test result is made out of two bytes. The
first byte is the result of the latest performed test, and the second byte is the result of
an on-going confidence test of the analog section of the controlling circuits.

A set bit (value of 1) indicates a fault.

BYTE 1

ANLG
MUX

DAC ANLG

REF

PWR
SUPPL

NOVR
AM_B

NOVR
AM_A

PROG
MEM

INT
RAM

INT_RAM Processor

Memory.

PROG_MEM Program

Memory.

NOVRAM_A Non-Volatile

Memory

A.

NOVRAM_B Non-Volatile

Memory

B.

PWR_SUPPL

Control circuits power supplies

ANLG_REF

Analog section reference voltage.

DAC

Digital to Analog Converter.

ANLG_MUX

Analog signal paths.

Light shaded bits are of tests performed during Power-On only.

Dark shaded bits are of tests performed during both Power-On and
Power Module Test.

BYTE 2

VSET

IOUT

VLOAD VOUT

VOUT

VOUT measurement confidence test.

VLOAD

VLOAD measurement confidence test.

IOUT

IOUT measurement confidence test.

VSET

VSET controlling signal confidence test.

XMP 2600 User’s Guide

rev. 1.0

97

Advertising