Printronix PrintNet Enterprise User Manual

Page 246

Advertising
background image

246

Chapter

6

Data Fields

The Source drop down menu is the data field for which the event is active.
The Value field allows you to specify the number you want the Source to be
compared. The Condition field indicates when exactly the related action takes
place.

The following conditions are available:

To set a forms counter, create two programmed entries,

Update LCD:Printing

and

Update LCD:Done

.

Update LCD:Printing

In the event that there is an unconditional change to the forms count,

Label Countdown

displays in the second line of the LCD.

Update LCD:Done

In the event that the forms count reaches zero, the message

Label

Printing Done

displays in the second line of the LCD.

Ready Signal

In the event that the forms count reaches zero, the printer will beep five
times.

NOTE:

When it is necessary to check/validate the value of a data field on a
certain event, the user has to map a “Data Field” action to the event
and check the “Evaluate” option. This will generate a “Data Field
Changed” event similar to when the data field actually changes.

Table 12. Conditions and Actions

Condition

None

No condition, action taken on each change of Source

(data field)

= =

‘Equal’ – action taken if Source equals Value

! =

‘Unequal’ – action taken if Source and Value are different

<

‘Smaller Than’ – action taken if Source is smaller than Value

< =

‘Smaller Than or Equal To’ – action taken if Source is smaller
than or equal to Value

>

‘Larger Than’ – action taken if Source is larger than Value

> =

‘Larger Than or Equal To’ – action taken if Source is larger
than or equal to Value

Advertising