Viewing Telemetry Data

293

Other Error Messages

Calibration Warning:

In some cases, the validator can determine if it is

out of calibration. When this occurs, the validator will communicate this
condition as part of a bar code report. This condition is considered a
warning and the printer will not stop.

NOTE:

If a bar code failure is also reported in the same bar code report, then
failure error handling will take precedence.

When the calibration warning condition is encountered, the message
“Validator needs calibration” displays. Normal operation will continue
during this warning. To clear the message, press the

PAUSE

key.

Once the message has been cleared, perform the calibration procedure
(see “Calibration” in the

Online Data Validator User’s Manual

). Whether or

not you perform a calibration will be unknown to the printer. Once the
warning message has been cleared, the printer will assume that any
problem has been resolved and will function as normal.

7

Decodeability

Unscannable code

Check media

8

PDF 417 Gap

Poor scanning

Check media

9

Calibration

Calibration

Warning

10

Overall Grade Failure

Overall Grade

Failure

11

Internal Data Format
Error

Error

Data invalid

12

Modulation

Modulation Fail

Check head&heat

13

Minimum Reflectance

RMin Fail

Check head&heat

14

(lowest)

Minimum Edge
Contrast

Edge Ctst Fail

Check head&heat

Priority

Failure Message

Operator Panel

Message