Preloaded Table

If a GPIO board is installed in the printer but no user defined mapping table
has been loaded, the printer will revert to a preloaded table.

Simple printer menus allow for programming three of the 11 (seven outputs,
four inputs) pre-defined interface signals to a particular polarity or logic
function that meets all typical print and apply requirements. They can also be
compatible with all the features available on other manufacturers’ external I/O
interfaces. This allows easy migration of Printronix T5000e or T5000r printers
to new or existing systems. Field interface is accomplished through an
industry standard 50-pin D type connector.

Input

Function

Notes

1

Reprint

Requires 16 Mbyte Printer Memory Option

2

Start Print

Polarity programmable via printer menu

3

Feed

4

Pause

5..8

Not Used

Output

Function

Notes

1

Ribbon Low

2

Ribbon Out

3

Media Out

4

Error/Service Required

5

End Print

8 modes selectable via printer menu

6

Data Ready/On Line

Selectable via printer menu

7

Not Used

8

Power On