CHAPTER 4 - SETTING THE SSW-07

29

English

4.2 KICK START

4.3 INITIAL

VOLTAGE

SETTING

Kick Start Enabling

DIP Switch

Figure 4.2 - Kick Start enabling

Soft-Starter SSW-07 offers a Kick Start function for loads that

present a large initial resistance to movement.

This function is enabled through the Kick Start DIP Switch. The

duration of the voltage pulse is set through the trimpot Kick Start

Time.

The voltage pulse applied is of 80 % Un during the programmed

trimpot Kick Start Time.

NOTE!

Use this function only for specific applications and where necessary.

Set the initial voltage to a value that the motor starts to run as soon

as the start command is given to the SSW-07.

The dot indicates

the factory default

setting

Initial Voltage

Setting Trimpot

Figure 4.3 - Initial voltage setting