I-View FDMO-2MIP-20XIR IP SpeedDome Network Camera User Manual

Page 64

Advertising
background image


63

3)

ALARM

The dome system has 2alarm inputs and 1 alarm
output. (Option0. When an alarm is received, an
input signal to the dome triggers the user defined
action (such as presets, patterns, etc.), and at
meantime the alarm output signals is activated.
ALARM NO.: Move the cursor to the ALARM
NO. Press IRIS OPEN to enter and move the
joystick up and down to select the alarm input no.
(Channel 1 and Channel 2)
INPUT STATE: Set the alarm contact status.
There are two input states, OPEN and CLOSE.
OPEN: Normally open
CLOSE: Normally close
ALARM MODE
OFF: Alarm function is deactivated.
ON: Alarm function is activated.
AUTO : AUTO Alarm function will be activated
and deactivated between START and STOP TIME.
ACTION: Set the alarm action:
NONE: No action. (Default)
PRESET: Dome goes to preset. (Default Preset 1)
SCAN: Dome starts auto scan (Default Scan 1)
SEQ: Dome runs auto cruise (Default Cruise 1)
PATTERN: Runs pattern scan (Default Pattern 1)
ALARM OUT: Set the auxiliary to activate:
OFF: Not alarm output will be activated.
OUT1: Alarm action will close AUX 1 output.
OUT2: Alarm action will activate AUX2 output.
RESET TIME: Set up time for the alarm output
(such as alarm buzzed) when is triggered.
START /STOP TIME: Set up the time to start
alarm and stop alarm ONLY under the AUTO
mode under ALARM MODE.

Advertising