OTHERS


The user can set up TEMP MODE, INTERNAL
FAN, PRESET FREEZE, STOP TIME. MENU
OFF TIME and NORTH ZERO here under the
menu of “OTHERS”

TEMP MODE: To set up the control mode of
dome fans and heaters. It includes three modes of
AUTO, FAN HIGH SPEED and FAN LOW
SPEED.

PRESET FREEZE:
This feature freezes the scene
on the monitor when going to a preset. This allows
smooth switching from one preset scene to another.

AUTO FLIP: When the camera tilts downward
and goes just beyond the vertical position, the
camera will rotate 180 degrees. The user can press
IRIS OPEN to enter and choose to turn on/off this
function.

STOP TIME: To set up the time that dome will
stops after receiving the last command. Options
include 5/15/30/60 Sec.

MENU OFF TIME: To set up the time that OSD

menu be off when no operations. Options include
1/2/5/10 min.
NORTH ZERO: To set up the due north of the
dome (pan 0º)
Move the cursor here and press IRIS OPEN to
enter. Move the joystick to control the dome to
pan 0º and press IRIS OPEN to confirm.