Ia net – IAI America XSEL-S User Manual

Page 19

Advertising
background image

13

IA Net

XSEL-R/S

3) Status LED Display 1

This shows the current condition of the power.

{

: Illuminating, × : OFF, ڏ : Flashing

Name

Lamp

condition

Color

Description

{

Green

Power ON

PWR

×

-

Power OFF

{

Orange Internal power

supply error

PSE

×

-

Internal power in

normal condition

{

Orange x Error in mounted

extension I/O

board

x

System

abnormality

ALM

(Note 1)

×

-

System Normal

ڏ

Orange x Reduction in

number of

stations

x

IA Net

communication

error

C-ERR

×

-

IA Net

communication in

normal condition

{

Green

IA Net

communication in

normal condition

with connected

controllers

LINK

×

-

Communication not

established with

connected

controllers

Note 1 : To cancel the alarm, it is necessary to reboot the

extension I/O unit.

However, alarm will be generated again unless

the cause of it is removed.

5) Unit Number Setting Rotary Switch

Set the occupied station for the extension I/O unit.

6) DIP Switch

Put all the switches 1 to 4 OFF when using.

ON

OFF

4) Status LED Display 2

This shows the current

condition of the power.

PWR

PSE

ALM

C-ERR

LINK

㪠㪆㪦㪊㩷㪩㪛㪰