Ia net, Xsel-r/s 3.2.1 setting of parameter in common – IAI America XSEL-S User Manual

Page 48

Advertising
background image

Chapter 3 Operation (Construction for Network)

42

IA Net

XSEL-R/S

3.2.1 Setting of Parameter in Common

The following settings must be established whenever IA Net is used.

[Setting 1: Setting of Top Occupied Station Number]

In I/O Parameter No.602, set the lowest occupied station number (settable range from 0 to 63)

that the controller occupies.

Shown below is an example for setting (when connecting four units of XSEL).

Shared Memory Area

Station No.

0

1

2

3

4

5

6

7

8

9

10

11

··

61

62

63

··

[Caution in Setting]

1 When setting the top occupied station number, do not attempt to duplicate the number

with another device. In IA Net, the specific XSEL controller units having duplicate

station numbers can not be detected. In case there is a duplication, an error “211/552:

IA Net Link Error” be issued.

2 Configuring spare station numbers into the network topology is advisable.When it is

required, set in I/O Parameter No.605 and 606 as the station not to be used in “IA Net

All Connected Station Patterns (31-00)/(63-32)”.

3 An extension I/O unit occupies four stations with multiples of 4 as the top station

number.

The unit numbers are determined by the shared station numbers. Set them on the

rotary switches.

Pay attention not to duplicate the station number when assigning in the shared

memory.

XSEL 1st Unit

(4 stations occupied)

XSEL 2nd Unit

(2 stations occupied)

XSEL 3rd Unit

(3 stations occupied)

XSEL 4th Unit

(1 station occupied)

No.602=0

No.602=6

No.602=4

No.602=11

Not used

Not used