Chapter 3 Operation (Construction for Network)

58

IA Net

XSEL-R/S

No.

Parameter Name

Example

for Setting Input Range

Remarks

707

Extension Input Port Start Number at

Extension I/O Unit Slot 1 Fixed

Assignment

1000

-1 to 3999 1000+(Multiples of 16)

(Setting is invalid if set to -1)

708

Extension Output Port Start Number

at Extension I/O Unit Slot 1 Fixed

Assignment

4000

-1 to 6999 4000+(Multiples of 16)

(Setting is invalid if set to -1)

709

Extension Input Port Start Number at

Extension I/O Unit Slot 2 Fixed

Assignment

1032

-1 to 3999 1000+(Multiples of 16)

(Setting is invalid if set to -1)

710

Extension Output Port Start Number

at Extension I/O Unit Slot 2 Fixed

Assignment

4016

-1 to 6999 4000+(Multiples of 16)

(Setting is invalid if set to -1)

711

Extension Input Port Start Number at

Extension I/O Unit Slot 3 Fixed

Assignment

-1

-1 to 3999 1000+(Multiples of 16)

(Setting is invalid if set to -1)

712

Extension Output Port Start Number

at Extension I/O Unit Slot 3 Fixed

Assignment

-1

-1 to 6999 4000+(Multiples of 16)

(Setting is invalid if set to -1)

713

Extension Input Port Start Number at

Extension I/O Unit Slot 4 Fixed

Assignment

-1

-1 to 3999 1000+(Multiples of 16)

(Setting is invalid if set to -1)

714

Extension Output Port Start Number

at Extension I/O Unit Slot 4 Fixed

Assignment

-1

-1 to 6999 4000+(Multiples of 16)

(Setting is invalid if set to -1)

715 Extension I/O Unit Error Monitoring

0

1

Set this to 1