Chapter 3 Operation (Construction for Network)

41

IA Net

XSEL-R/S

Station Numbers and Shared Word Numbers on Extension I/O Unit

Rotary Switch

(unit number

setting)

Station No.

Shared Word

No.

0

0 to 3

0 to 15

1

4 to 7

16 to 31

2

8 to 11

32 to 47

3

12 to 15

48 to 63

4

16 to 19

64 to 79

5

20 to 23

80 to 95

6

24 to 27

96 to 111

7

28 to 31

112 to 127

8

32 to 35

128 to 143

9

36 to 39

144 to 159

A

40 to 43

160 to 175

B

44 to 47

176 to 191

C

48 to 51

192 to 207

D

52 to 55

208 to 223

E

56 to 59

224 to 239

F

60 to 63

240 to 255

XSEL1

XSEL2

XSEL3

Slot

No.

Input

Output

Input

Output

Input

Output

1

ż

(32 points)

2

ż

(16 points)

3

ż

(16 points)

ż

(32 points)

4

ż

(48 points)

Parameters

No.705

2

10

2300

XSEL First Units

IA Net Related Parameters

Set Value

1

I/O Port Allocation Type

0

602 Top Occupied Station Number

0

603 Resizing executed station number

0

604 Final station number

15

605 All Connected Station Patterns (31-00)

F1FF

606 All Connected Station Patterns (63-32)

0

691 Input Port Start No. in Network I/F

1000

692 Output Port Start No. in Network I/F

4000

693 Shared memory reference word pattern (31-00)

(Note 1)

01070000

694 Shared memory reference word pattern (63-32)

(Note 1)

1000000

695

to

700 Shared memory reference word pattern

(255-64)

(Note 1)

0

701 Output Ports

(Note 2)

208

705 Extension I/O Unit Use Select

2

706 Unit Number of Extension I/O Unit

3

707 Start number of extension input ports at

fixed assignment for Slot 1

1080

708 Start number of extension output ports at

fixed assignment for Slot 1

-1

709 Start number of extension input ports at

fixed assignment for Slot 2

-1

710 Start number of extension output ports at

fixed assignment for Slot 2

-1

711 Start number of extension input ports at

fixed assignment for Slot 3

-1

712 Start number of extension output ports at

fixed assignment for Slot 3

-1

713 Start number of extension input ports at

fixed assignment for Slot 4

-1

714 Start number of extension output ports at

fixed assignment for Slot 4

-1

XSEL Secound Units

IA Net Related Parameters

Set Value

1

I/O Port Allocation Type

0

602 Top Occupied Station Number

4

603 Resizing executed station number

0

604 Final station number

15

605 All Connected Station Patterns (31-00)

F1FF

606 All Connected Station Patterns (63-32)

0

691 Input Port Start No. in Network I/F

1000

692 Output Port Start No. in Network I/F

4000

693 Shared memory reference word pattern (31-00)

(Note 1)

100001FF

694 Shared memory reference word pattern (63-32)

(Note 1)

10003

695

to

700 Shared memory reference word pattern

(255-64)

(Note 1)

0

701 Output Ports

(Note 2)

80

705 Extension I/O Unit Use Select

10

706 Unit Number of Extension I/O Unit

3

707 Start number of extension input ports at

fixed assignment for Slot 1

-1

708 Start number of extension output ports at

fixed assignment for Slot 1

-1

709 Start number of extension input ports at

fixed assignment for Slot 2

-1

710 Start number of extension output ports at

fixed assignment for Slot 2

4080

711 Start number of extension input ports at

fixed assignment for Slot 3

-1

712 Start number of extension output ports at

fixed assignment for Slot 3

-1

713 Start number of extension input ports at

fixed assignment for Slot 4

-1

714 Start number of extension output ports at

fixed assignment for Slot 4

-1

XSEL Third Units

IA Net Related Parameters

Set Value

1

I/O Port Allocation Type

0

602 Top Occupied Station Number

7

603 Resizing executed station number

0

604 Final station number

15

605 All Connected Station Patterns (31-00)

F1FF

606 All Connected Station Patterns (63-32)

0

691 Input Port Start No. in Network I/F

1000

692 Output Port Start No. in Network I/F

4000

693 Shared memory reference word pattern (31-00)

(Note 1)

00191E03

694 Shared memory reference word pattern (63-32)

(Note 1)

30000

695

to

700 Shared memory reference word pattern

(255-64)

(Note 1)

0

701 Output Ports

(Note 2)

32

705 Extension I/O Unit Use Select

2300

706 Unit Number of Extension I/O Unit

3

707 Start number of extension input ports at

fixed assignment for Slot 1

-1

708 Start number of extension output ports at

fixed assignment for Slot 1

-1

709 Start number of extension input ports at

fixed assignment for Slot 2

-1

710 Start number of extension output ports at

fixed assignment for Slot 2

-1

711 Start number of extension input ports at

fixed assignment for Slot 3

1176

712 Start number of extension output ports at

fixed assignment for Slot 3

4032

713 Start number of extension input ports at

fixed assignment for Slot 4

1192

714 Start number of extension output ports at

fixed assignment for Slot 4

-1

Extension I/O unit

input ports connected directly excluded

Extension I/O unit

input ports connected directly excluded

Expansion I/O units

Rotary Switch (unit number setting)

3

Number of I/O points for Slot 1

I/O=32/16

Number of I/O points for Slot 2

I/O=32/16

Number of I/O points for Slot 3

I/O=16/32

Number of I/O points for Slot 4

I/O=48/48

Note 1 Establish the settings with a care not to include the input ports

of an extension I/O unit that XSEL controller directly controls

(which is set in Parameter No. 705) in the word pattern.

Note 2 Establish the settings with a care not to include the output ports

of an extension I/O unit that XSEL controller directly controls

(which is set in Parameter No. 705) in the number of used

output ports.