Chapter 3 Operation (Construction for Network)

56

IA Net

XSEL-R/S

3.3 Operation

Caution 1) XSEL controllers check the links of all the stations set in I/O Parameters

No.605 and 606 at the startup, and will generate “211/552: IA Net Link Error”

in case any of the stations was not confirmed. Therefore, it is recommended

to have the power supplied to all the units connected to IA Net is turned ON at

the same time.

* The time to wait for the link establishment can be changed in Bits 24 to 34:

Timeout duration (sec) for link waiting at IA Net initializing in I/O Parameter

No.608 “IA Net Attribute 1”. (Initial setting = 15sec)

2) If the software reset is conducted or the power is turned OFF on a station in

the link with I/O Parameter No.607 “IA Net Error Monitor” set to 1 (Valid),

controllers on other stations will issue “211/552: IA Net Link Error”.

To avoid the link error at the startup, it is suggested to set IA Net Error Monitor

to 0 (Invalid) temporarily, or reboot the power to all the connected stations at

the same time.

3) The shared data of a station with an error in IA Net network is unreliable.

3.3.1 Example for Extension I/O Unit Connection

Connect an extension I/O unit to an XSEL controller through IA Net.

Shown below is an example for parameter settings assuming an I/O port with 32 points of output

and 64 point of input (occupies two slots) is used.

Listed below is the usage condition.

x

Usage Conditioin

Item

XSEL

Extension I/O

Units

Remarks

Top Station No.

0

4

XSEL occupies 2 stations,

Extension I/O unit occupies 4 stations

Extension I/O Unit No.

1

Number of Output Points

0

32

Number of Input Points

0

64

Assign to the I/O boards in Slot 0 and 1

Used Extension Input Port Start No.

1000

Use in fixed assignment

Used Extension Output Port Start

No.

4000

Use in fixed assignment

IA Net Connection

Extension I/O Unit (Unit No.0)

Slot 0 : Input 32 Points, Output 16 Points

Slot 1 : Input 32 Points, Output 16 Points

XSEL