Ia net, Xsel-r/s – IAI America XSEL-S User Manual

Page 54

Advertising
background image

Chapter 3 Operation (Construction for Network)

48

IA Net

XSEL-R/S

[Setting 2: Selection of Unit Number of Extension I/O Unit]

No.

Parameter Name

(I/O parameters)

Initial Value

(Reference)

Input Range

Remarks

706

Extension I/O Unit Number

0

H

0 to F

H

Set the unit number of the extension I/O

unit to be connected.

Set the unit number (0 to F) on the rotary switch in the extension I/O unit.

Set the same value as set on the rotary switch in Extension I/O Unit Parameter No.706

“Extension I/O Unit No.” in a hexadecimal number.

An extension I/O unit occupies four stations with multiples of 4 as the top station number. Pay

attention not to duplicate the station number when assigning in the shared memory.



Setting Value for

Unit Number

Occupied Station of

Extension I/O Unit

0

0 to 3

1

4 to 7

2

8 to 11

3

12 to 15

4

16 to 19

5

20 to 23

6

24 to 27

7

28 to 31

8

32 to 35

9

36 to 39

A

40 to 43

B

44 to 47

C

48 to 51

D

52 to 55

E

56 to 59

F

60 to 63

Rotary Switch

Advertising