Chapter 3 Operation (Construction for Network)

36

IA Net

XSEL-R/S

(3) Only one unit of the extension I/O unit can be connected to one unit of XSEL.

Make the extension I/O unit related to each XSEL with care to satisfy the required number of

output points defined in (2) and not to assign to the I/O board mounted in multiple I/O units.

Write the total number of input on the I/O board mounted in the related slot to the number of

input points on the extension I/O.

Draw extension I/O units below each XSEL in the diagram drawn in (Preparation) and also

draw arrows to show the relations.

Note One piece of I/O board (output port) cannot be controlled by multiple XSEL.

(Even if there is an excess output port, another XSEL cannot be assigned.)

Have the assignments based on the system construction map created by now.Print out the shared

memory assignment table and parameter setting table in the appendix in the end of this manual,

and write them down.

[Refer to [2] Examples for Parameter Setting and Shared Memory Assignment in the next page

and sections 3.2.1 to 3.2.4]

x Basic Flow to Create Assignment Table

Connected

to slot 1 to 3

Extension I/O

Unit 1)

1 2 3 4

Connected to

slot 4

Extension I/O

Unit 2)

1 2 3 4

Connected to

slot 1 to 4

Extension I/O

Unit 4)

Extension I/O

Unit 3)

1 2 3 4

1 2 3 4

Multiple

connected to

extension I/O units

XSEL

1st Unit

XSEL

2nd Unit

XSEL

3rd Unit

XSEL

nth Unit

XSEL Unit Number = Next Number

Yes

XSEL Unit Number = No. 1

Assign the output ports (those on occupied extension I/O units

excluded)

Assign the output ports on the occupied extension I/O units

Is the total four or less for occupied stations

on one unit of XSEL?

No

No

Yes

To the next page

Is assignment of outputs on all the connected

XSEL units completed?