Ia net – IAI America XSEL-S User Manual

Page 61

Advertising
background image

Chapter 3 Operation (Construction for Network)

55

IA Net

XSEL-R/S

[3) Connected Controller Change]

Changing the controller to connect to is able to perform in the XSEL PC software from the menu

“Controller (C)”

ĺ

“IA Net Connection Change (U)”. The connection setting window appears.

Change the controller to connect to in the same way as conducted when selected the controller

to connect to. [Refer to 2) Connected Controller Setting]

Note 1 If the connection of the PC software is established through IA Net, it requires more time to

complete the operation compared to the case of being connected directly to TP Port.

Connect the PC software directly to TP port on the XSEL controller to be edited if

necessary.

Note 2 It is recommended to have the baud rate setting at 115200bps when connecting to the PC

software through IA Net.

Note 3 The number of XSEL controller that the XSEL PC software can be connected is only one. It

cannot be connected to multiple units at the same time.

Note 4 When connecting the PC software, set the mode to MANU Mode on the XSEL controller to

be referred to through the IA Net network (that is connected to TP port) and on the

controller that the data edit is to be conducted. The PC software cannot be connected in

AUTO Mode.

Note 5 When a command of TP Port connection and another of connection via IA Net are

executed on one XSEL controller at the same time, the priority is put on the connection

from TP Port. (The connection via IA Net will be disconnected.)

Note 6 In the case IA Net is in the link error condition, the connection via IA Net cannot be

established. It is recommended to set I/O Parameter No.607 “IA Net Error Monitor” to 1

(Monitor) when having a connection via IA Net.

Note 7 With the connection via IA Net, it is possible to check the operation of XSEL controller in a

distanced place. However, considering a case the operation became unstable due to such

reasons as a communication error, it is recommended that an emergency stop switch for

the connected controllers is prepared within the reach so the axes can be immediately

stopped in emergency.