Chapter 4

Appendix

65

IA Net

XSEL-R/S

No.

Parameter Name

Initial Value

(Reference) Input Range

Remarks

716

Extension I/O Unit

Multi-Channel DIO External

Terminal Block Overcurrent /

Power Supply Failure

Detection Input Indication

0

H

0 to

FFFFFFFF

H

Bits 0 to 3

: Extension I/O unit slot 1 input

indication

Bits 4 to 7

: Extension I/O unit slot 2 input

indication

Bits 8 to 11 : Extension I/O unit slot 3 input

indication

Bits 12 to 15 : Extension I/O unit slot 4 input

indication

(0: Error detection not to be input

1: Error detection input = use IN023 in card

2: Error detection input = use IN047 in card

3: Error detection input = use IN023/47 in card)

(Note) See the specification of the connected

terminal unit for the multi-channel DIO for

setting.

(Note) The input port used as the error detection

input cannot be used as a

general-purposed input port.