Ia net, Xsel-r/s, Chapter 3 operation (construction for network) – IAI America XSEL-S User Manual

Page 63: Xexample for i/o parameter settings

Advertising
background image

Chapter 3 Operation (Construction for Network)

57

IA Net

XSEL-R/S

x

Example for I/O Parameter Settings

No.

Parameter Name

Example

for Setting Input Range

Remarks

1 I/O Port Allocation Type

0

0 to 1

0 : Fixed Allocation

1 : Automatic Allocation

602 IA Net Occupied Station Top No.

0

0 to 63

603 IA Net Resizing Executed Station No.

0

0 to 63

Station number to optimize the communication

cycle time at the IA Net startup

604 IA Net Final Station No.

7

1 to 63

In this example, the extension I/O unit uses

only two slots, 1 and 2, but station assignment

requires four stations.

(Stations No. 4 to 7)

605 IA Net All Connected Station Patterns

(31-00)

0

H

0 to

FFFFFFFF

H

As described in this example, optimized

setting can be automatically established if

writing with setting 0 when connecting only an

XSEL controller and an extension I/O unit.

606 IA Net All Connected Station Patterns

(63-32)

0

H

0 to

FFFFFFFF

H

With 0: Disconnected and 1: Connected,

make the connection conditions of Stations

No.63 to No.32 in bit patterns and convert

them into the hexadecimal numbers to input.

705 Extension I/O Unit Use Select

33

H

0 to

FFFFFFFF

H

Bits 0 to 3

: Slot 1 Use Select

Bits 4 to 7

: Slot 2 Use Select

Bits 8 to 11 : Slot 3 Use Select

Bits 12 to 15 : Slot 4 Use Select

Set Value: (0 : Unused,

1 : Only output to be used,

2 : Only input to be used,

3 : Input and output to be used)

706 Extension I/O Unit No.

1

H

0 to F

H

Set the unit number of the extension I/O unit to

be connected.