Ia net, Xsel-r/s – IAI America XSEL-S User Manual

Page 58

Advertising
background image

Chapter 3 Operation (Construction for Network)

52

IA Net

XSEL-R/S

The bit data of the values set in No.693 to 700 are converted into the hexadecimal numbers for

settings.

Shown below is an example for No.693.

The value to set in No.693 is 8CEF0321

H

.



Reference Matching Table for Bit Data (Binary Numbers)

and Hexadecimal Numbers

Bit Data

(Binary Numbers)

Hexadecimal

Numbers

0000

0

0001

1

0010

2

0011

3

0100

4

0101

5

0110

6

0111

7

1000

8

1001

9

1010

A

1011

B

1100

C

1101

D

1110

E

1111

F



[Setting 2 : Output Port Settings]

1) Number of Used Ports Setting

No.

Parameter Name

(I/O parameters)

Initial Value

(Reference)

Input Range

Remarks

701 IA Net Shared Number of

Output Use

0

0 to 256

Multiples of 16

* One station is occupied for every 64

points.

Set the number of the ports used for the output in IA Net in I/O Parameter No.701.

Note 1

The number of occupied stations is determined by the number of used output

ports.

Number of

Points used for

Output

Number of Occupied

Stations

0

0

16 to 64㩷

1㩷

80 to 128㩷

2㩷

144 to 192㩷

3㩷

208 to 256㩷

4㩷

Settings in No.693 1 0 0 0 1 1 0 0 1 1 1 0 1 1 1 1 0 0 0 0 0 0 1 1 0 0 1 0 0 0 0 1

Ļ

Ļ

Ļ

Ļ

Ļ

Ļ

Ļ

Ļ

Ļ

(Covert into

hexadecimal

numbers)

8

C

E

F

0

3

2

1

Advertising