Chapter 4

Appendix

68

IA Net

XSEL-R/S

Error

Code

Error Name

Check Items

Check/Treatment

548

IA Net Resizing

Overlapping Error

Aren’t there several stations to execute

resizing?

Check that the value set in I/O Parameter

No.603 “IA Net Resizing Executed Station

No.” matches to the controller in the same

network.

Check if the station number is exceeding

63.

Check the values in I/O Parameters No.601

“IA Net Occupied Station No.”, No.602 “IA Net

Top Occupied Station Number” and No.604

“IA Net Final Station Number”.

Check if the station number of the

controller itself is exceeding the final

station number.

Confirm that the value set in I/O Parameter

No.602 “IA Net Occupied Station Top No.” is

smaller than what is set in I/O Parameter

No.604 “IA Net Final Station No.”.

Isn’t the resizing executed station

number exceeding the final station

number?

Confirm that the value set in I/O Parameter

No.603 “IA Net Resizing Executed Station

No.” is smaller than what is set in I/O

Parameter No.604 “IA Net Final Station No.”.

Check if the controller itself is being

subject to the resizing executed station.

Confirm that the value set in I/O Parameter

No.603 “IA Net Resizing Executed Station

No.” is the same as what is set in No.602 “IA

Net Occupied Station Top No.”.

Is the controller itself involved in the all

connected stations pattern parameter?

Check if all the stations in the controller are

set in I/O Parameters No.605 and 606 “IA Net

All Connected Station Patterns

(31-00)/(63-32)”.

54C

IA Net Communication

Parameter Error

Isn’t the all connected stations parameter

including a station number later than the

final station number?

Check if no station number later than what is

set in I/O Parameter No.604 “IA Net Final

Station Number” is set in I/O Parameters

No.605 and 606 “IA Net All Connected Station

Patterns (31-00)/(63-32)”.

560

IA Net Number of

Occupied Stations

Overflow Error

Check if the total of the occupied number

determined by the number of the I/O

communication use Output points and

occupied number determined by the

number of the extension I/O unit DO use

exceeds four stations.

Confirm the number of occupied stations from

I/O Parameter No.701 “IA Net Shared

Number of Outputs Use” and No.705

“Extension I/O Unit Use Select”.

561

IA Net I/O Assignment

Number Overflow Error

Isn’t the number of the shared word to

acquire from exceeding 16?

Make sure that the total number of ON bits in

I/O Parameters No.693 to 700 “IA Net

Common Input Acquisition Shared Word

Patterns” is not exceeding 16 bits.

Check if the station numbers for X-SEL

and the extension I/O unit are duplicated.

Check the values in I/O Parameters No.602

“IA Net Occupied Station Top No.” and No.706

“Extension I/O Unit No.”.

Check if trying to use an extension I/O

unit with a greater station number than

what it is for I/O Parameter No.604 “IA

Net Final Station Number”.

Check the values in I/O Parameters No.604

“IA Net Final Station No.” and No.706

“Extension I/O Unit No.”.

562

Extension I/O Unit

Parameter Error

Isn’t an extension I/O unit being subject

to resizing executed station?

Check the values in I/O Parameters No.603

“IA Net Resizing Executed Station No.” and

No.706 “Extension I/O Unit No.”.

563

Extension I/O Unit DO

Duplication Error

Aren’t another X-SEL controller and an

extension I/O unit used DO competing

with each other?

DO cannot be used for multiple XSEL at the

same time. Revise the setting in I/O

Parameter No.705 “Extension I/O Unit Use

Select”.

Check the extension I/O unit is

connected to IA Net.

Check the conditions of 24V power supply for

extension I/O units, IA Net cables and the

mount of the terminal resistors.

564

Extension I/O Unit Initial

Communication Timeout

Error

Is the extension I/O unit set in the

parameter matching with the station

number actually connected?

Make sure the number set in I/O Parameter

No.706 “Extension I/O Unit No.” is matching

with the condition of the unit number setting

switch on the extension I/O unit.

565

Extension I/O Unit

Board Undetected Error

Is the I/O slot that you are trying to use

equipped with DIO boards?

Confirm that an I/O slot with no DIO board

mounted on is not set to be used in the setting

of I/O Parameter No.705 “Extension I/O Unit

Use Select”.

567

IA Net Communication

Cycle Time Error

Check that the same final station number

as the resizing executed station is set to

the final station number.

Confirm that the setting in I/O Parameter

No.604 “IA Net Final Station No.” is the same

in all the controllers.

Advertising