Example for Shared Memory Assignment

XSEL 1st Unit

XSEL 2nd Unit + Extension

XSEL 3rd Unit + Extension I/O

Station No.

Shared

word

No.

Occupations

of Shared

Memory

Input

Output

Input

Output

Input

Output

0

4015 to 4000

ĺ 1015 to 1000

ĺ

1015 to 1000

1

4031 to 4016

ĺ 1031 to 1016

ĺ

1031 to 1016

2

4047 to 4032

ĺ 1047 to 1032

0

3

4063 to 4048

ĺ 1063 to 1048

4

4079 to 4064

ĺ 1079 to 1064

5

4095 to 4080

ĺ 1095 to 1080

6

4111 to 4096

ĺ 1111 to 1096

1

7

4127 to 4112

ĺ 1127 to 1112

8

4143 to 4128

ĺ 1143 to 1128

9

4159 to 4144

ĺ

1047 to 1032

10

4175 to 4160

ĺ

1063 to 1048

2

11

4191 to 4176

ĺ

1079 to 1064

12

4207 to 4192

ĺ

1095 to 1080

13

14

1st

Unit

3

15

Output

Occupations

(208 points)

16

1015 to 1000

ĸ

4015 to 4000

ĺ

1111 to 1096

17

1031 to 1016

ĸ

4031 to 4016

18

1047 to 1032

ĸ

4047 to 4032

4

19

4063 to 4048

ĺ

1127 to 1112

20

4079 to 4064

ĺ

1143 to 1128

21

22

5

23

Output

Occupations

(80 points)

24

1063 to 1048

ĸ

4095 to 4080

25

26

2nd

Unit

6

27

Extension

I/O unit

Output

Occupations

(16 points)

28

1159 to 1144

ĸ

4015 to 4000

29

4031 to 4016

30

7

31

Output

Occupations

(32 point)

32

1175 to 1160

ĸ

4047 to 4032

33

1191 to 1176

ĸ

4063 to 4048

34

3rd

Unit

8

35

Extension

I/O unit

Output

Occupations

(32 points)

36

37

38

9

39

40

41

42

10

43

44

45

46

Empty

11

47

Empty

(for station

number

adjustment)

48

1095 to 1080

ĺ 1207 to 1192

ĺ

1159 to 1144

49

1111 to 1096

ĺ

ĺ

1175 to 1160

50

Slot

1

12

51

Slot 1

Input

(32 points)

52

53

54

Slot

2

13

55

Slot 2

Input

(None)

56

1079 to 1064

ĸ

ĸ

1191 to 1176

57

58

Slot

3

14

59

Slot 3

Input

(16 points)

60

1207 to 1192

61

1223 to 1208

62

1239 to 1224

Extensi

on

I/O

un

it

(INPUT)

Slot

4

15

63

Slot 4

Input

(48 points)

Procedure

(4)(7)

Procedure

(10)(11)

Procedure

(10)(11)

Procedure

(10)(11)

Procedure

(12)(16)

Extension I/O

unit

input

ports

connected

directly to 1st

unit of XSEL

(assigned

after the

reference

ports)

Reference

Ports

Reference ports

(to be assigned

prior to extension

I/O unit input

ports)

Procedure (4)

ĸ

Procedure

(10)(11)

Procedure

(4)(7)

Procedure ĺ

(5)(7)

Procedure (10)

ĸProcedure (10)

ĸ

Procedure

(10)(11)

Procedure

(5)(7)

ĸProcedure (14)

Procedure (8)

ĸ

Procedure

(14)(15)

Procedure

(12)(13)(16)

Extension I/O unit input ports connected directly to 1st unit of XSEL

Procedure

(12)(13)(16)

Procedure

(10)(11)

Procedure

(10)(11)

Procedure

(14)(15)