Chapter 4

Appendix

66

IA Net

XSEL-R/S

x

Other Parameters

No.

Parameter Name

Initial Value

(Reference) Input Range

Remarks

49 Classification of Panel

7-Segment Display Data

0

0 to 9

0 : Controller Status Display

1 : Motor Current Indicator Display

The current pattern of each axis is displayed

instead of “Ready Status Display” and “Program

Executing Number Display”.

“Indicator Display Axis No. MIN” (on the right

end column) is to be indicated in “Other

Parameters No.50”.

2 : User Information Number Display (U001 to

U999)

User information number is displayed instead of

“Ready Status Display” and “Program

Executing Number Display” when the user

information number is other than 0.

“User Information Number Indication Global

Integral Variable Number” is to e indicated in

“Other Parameters No.50”.

3 : IA Net Station Number Display (IA00 to IA63)

IA Net Occupied Station Top Number is

displayed instead of “Ready Status Display”

only when IA Net is used.

[Example] for IA Net Station No.63, the display

is as shown below.

Last 2 digits show the statin number.