Ia net – IAI America XSEL-S User Manual

Page 38

Advertising
background image

Chapter 3 Operation (Construction for Network)

32

IA Net

XSEL-R/S

3.1.4 Functions of IA Net

IA Net possesses three communication functions.

(1) I/O communication among XSEL controllers

(2) I/O communication of extension I/O unit

(3) Connection of PC software with XSEL controllers

[1] Guideline of I/O Communication among XSEL Controllers

The diagram below shows the flow of PIO signals between two units of XSEL

The condition of the extension output port that is turned ON/OFF on X-SEL1 can be written

from the extension input port on X-SEL2 via the shared memory. At the same time, the

condition of the extension output port that is turned on/off on X-SEL2 can be written from the

extension input port on X-SEL1.

X-SEL can turn ON/OFF from the extension output port only on the stations that it occupies.

The stations other than what are occupied cannot be turned ON/OFF. The condition of ON/OFF

can be referred (read) from all the XSEL controllers connected to the IA Net network.

4015 to 4000 → No.0 → 1015 to 1000

4031 to 4016 → No.1 → 1031 to 1016

4047 to 4032 → No.2 → 1047 to 1032

4063 to 4048 → No.3 → 1063 to 1048

No.4

No.5

No.6

No.7

1015 to 1000 ← No.8 ← 4015 to 4000

1031 to 1016 ← No.9 ← 4031 to 4016

1047 to 1032 ← No.10 ← 4047 to 4032

1063 to 1048 ← No.11 ← 4063 to 4048

No.12

No.13

No.14

No.15

No.16

No.17

No.18

Occupied stations for X-SEL 1
Occupied stations for X-SEL 2

St.

No.0

St.

No.1

St.

No.2

St.

No.3

Extension Input Port No.

Extension Input Port No.

Extension Output Port No.

X-SEL 1

Top Station

No.0

X-SEL 2

Top Station

No.2

IA Net

Shared Memory

<Writing>

<Writing>

<Reading>

<Reading>

Extension Output Port No.

Advertising
This manual is related to the following products: