3. Installation and W

iring

3.6

Wiring the Power Supply

Connect the positive side and negative side of the 24-VDC power supply to the 24-V terminal and 0-V terminal on
the power-supply terminal block, respectively.

Use a wire satisfying the following specifications.

Item Specification

Applicable wire

Twisted wire: AWG 22 (0.3 mm

2

) (copper wire)

(Note) Provide proper termination to prevent shorting due to contact with wire offcut.

If the wiring path is long, provide a relay terminal block and connect the
original wire to another wire of a different size.

Temperature rating of
isolation sheath

60

qC or above

Length of bare wire

3.7

Wiring the Brake Forced-release Switch

If the actuator is equipped with a brake, provide a forced-release switch to permit a reset means during startup
adjustment or in case of emergency.
The customer must provide the switch (24 VDC, with a minimum contact capacity of 0.2 A).
Connect one side of the switch to the positive side of the 24-VDC power supply, and connect the other side to the
BK terminal on the power-supply terminal block.
The brake will be released when the switch is closed.

Danger: If the actuator is oriented vertically, exercise due caution when releasing the brake to prevent the

slider/rod from dropping unexpectedly to pinch your hand or damage the robot hand or load.

Push with a flat-head
screwdriver to open the cable
inlet.

Input power supply
24 VDC

Power-supply

terminal block

Cable inlet

Input power

supply

Relay terminal block Power-supply terminal block

Brake forced-release
switch

Input power supply
24 VDC

Power-supply

terminal block

Advertising