41

5. Operation Using I/O Signals

5.1.2

External Output Specifications

Item Specification

Number of output points

6 points

Rated load voltage

24 VDC

Maximum current

50 mA per point

Residual voltage

Max. 2 V

Insolation method

Photocoupler

Internal circuit configuration

[NPN specification]

[PNP specification]

Controller

Controller

+24-V external

power supply

+24-V external

power supply

Internal circuit

Internal circuit

Each output

Each output

Load

Load

Load

Load