5. Operation Using I/O Signals

Front end move

command input (ST1)

Front end detection

output (LS1)

Speed

Time

Moving Stopped Moving

Front end

z Pausing during Movement

Move commands are implemented based on signal levels. Accordingly, the actuator moves while the signal is
ON, and once the signal turns OFF, the actuator will decelerate to a stop and the operation will end.
If you want to pause the actuator as a secondary safety measure, turn the move command signals OFF.

(Example) Pausing the actuator while moving toward the front end

z Forced Return in Case of Emergency

The following example explains how to return the actuator to the standby position (rear end) after an
emergency situation occurred while the actuator was moving.

(Example) Return the actuator to the standby position (rear end) after an emergency situation occurred while

the actuator was moving toward the front end

Operation timings

PLC processing 1: Upon occurrence of an emergency situation, the rear end move command signal (ST0)

turns ON, and then the front end move command signal (ST1) turns OFF.

Operation:

[1] After the front end move command signal (ST1) turns OFF, the actuator

decelerates to a stop.

[2] The actuator reverses its direction and starts moving toward the rear end.
[3] When the actuator reaches the rear end, the rear end positioning complete output

(PE0) turns ON.

PLC processing 2: The rear end move command signal (ST0) turns OFF.

Occurrence of

emergency situation

Front end move

command input (ST1)

Rear end move

command input (ST0)

Rear end detection

output (LS0)

Moving to + direction

Moving to - direction

Rear end

Time