IAI America ACON-CY User Manual

Page 40

Advertising
background image

28

3. Installation and W

iring

Use an SIO converter if it is desired to stop the entire system urgently by emergent stop via the teaching pendant.
The operation on the emergency stop switch of the teaching pendant can also be reflected when a gateway unit is
used as well.

Precautions on power supply and emergency stop circuit

*1 Refer to the specification list for the load current conducted per controller.
*2 The input current to the EMG- terminal per controller is 5 mA. When connecting a relay contact CR to

EMG- terminals of several controllers, make sure to check the capacity of the relay contact.

*3 When the teaching pendant is inserted to a controller, the controller automatically recognizes that it is

connected.

EMG signal
detection (H)

Time

constant

Drive stop signal (L)

Motor

drive

circuit

External
EMG
reset
switch

External
EMG
circuit

Motor
power
supply

Controller
power supply

Controller 2

Controller n

Under normal
circumstances, it
is jumpered. If the
safety category
requires shutting
down motor
driving source,
use the following
circuit (the same
timing as EMG).

The brake is turned
on/off automatically
by turning on/off of
the servo. To
release the brake
manually, close the
brake release
switch.

* The brake release

switch shall be
prepared by the
customer.

(Switch)

24 VDC
Contact capacity
0.2 A or higher

Port switch

SIO
connector

Connection

detection

circuit

Brake release
switch

EMG switch of
teaching pendant

SIO

communication

EMG switch of
teaching pendant

Port switch