10 connecting the i/o flat cable – IAI America ACON-CY User Manual

Page 43

Advertising
background image

31

3. Installation and W

iring

3.10 Connecting the I/O Flat Cable

Signal name

No.

In case of solenoid valve mode 0

In case of solenoid valve mode 1

Color Wiring

1

24 V

Brown-1

2

0 V

Red-1

3

Rear end move command input

Rear end move command

Orange-1

4

Front end move command input

Front end move command

Yellow-1

5

Intermediate point move
command input

Intermediate point move
command

Green-1

6

Servo-on command input

Servo-on command input

Blue-1

7

Rear end detection output

Rear end positioning complete
output

Purple-1

8

Front end detection output

Front end positioning complete
output

Gray-1

9

Intermediate point detection
output

Intermediate point positioning
complete output

White-1

10 Ready output

Zone output

Black-1

11 Homing complete output

Homing complete output

Brown-2

12 Alarm output

Alarm output

Red-2

Flat cable

(pressure-

welded)

Warning: When checking the continuity of the flat cable, exercise due caution not to bend the female

pins on the connector outward. It may cause contact failure, resulting in malfunction.

Red 2

Brown 1

Cable type:

Housing: 51353-1200

(MOLEX)

Contact: 56134-9000

(MOLEX)

Advertising