5. Operation Using I/O Signals

Warning:

Since a servo motor is applied as the driving motor, the system performs the excitation
phase detection in the first servo ON process after the power is turned ON.
Therefore, it is necessary that the actuator is free for operation when the servo is turned ON.
It may disturb the excitation pole detection work properly and may cause such problems as
an abnormal operation or the excitation detection error if the slider or the rod is touching
the mechanical end or the work piece is interfering with the surrounding devices.
In such a case, move the actuator by hand to a position where it can be operated freely.
If the unit is equipped with a brake, it is necessary to release the brake manually by putting
the brake release switch ON. Be careful, the slide or rod may drop due to the payload on
the actuator. Be sure to avoid any damage or injuries from the load moving.
If the actuator cannot be moved by hand, there is an option to change Parameter No.28
(Excitation Pole Signal Detection Direction) setting. However, please contact us in advance
if you desire to do so.