Restart All - Restarts any sequences or counts you may have set on other buttons. The
example on the right illustrates how the Restart All action works. This example reads
"Look for a sequence of five SSP Frames and then trigger. If, however, an Error occurs
any time before the fifth SSP frame has occurred, restart the count".

External Trigger Pulse HIGH, Pulse LOW, Pulse TOGGLE - Causes the event send an
external signal out through the External Out port on the back of the CATC 10K. The
shape of the signal (Pulse HIGH, Pulse LOW or Pulse TOGGLE) must be the same for
all events sending out such signal. This means that if you change the output signal for
one event, it will automatically change the signal for all other events sending output
signals.

Properties - Displays the Action Properties dialog for the selected state.

Restart example. In this configuration,
the analyzer will restart its search for a
sequence of 5 SSP frames if an error is
encountered.

Second restart example. In this

configuration, the analyzer will restart
its search for the above sequence of
events if a SCSI command is found.