Branch to New State

This option is shown only for sequences, not for Global Rules which can contain only one
state. The Branch to New State action is similar to the Branch to Existing State action
defined above, however this option automatically create a new (but empty) state in the
scenario. If there are currently "n" states in the scenario, the new state will be "State N"
(because states always start with State 0).

Beep

The Beep action produces an audible beep to alert the user to various events that have
occurred. The beep can be specified as a duration of 250 ms or of 1 sec. Multiple beeps
could be created in a sequence by branching to a new state which waits for a short time
and then issues a second beep.

SMA Output

The SMA Output action produces a signal to an external device. The type and duration
of the signal can be controlled by the parameters listed in the action, as follows:

The signal created by the SMA Output action appears as a TTL level signal on the "EXT
OUT" connector at the rear of the Avalanche unit.

BOB Output - TRIG

The BOB (Break Out Board) Output -TRIG action produces a TTL level signal on one of
the two outputs on the breakout board (which is connected to the analyzer via the Data
In/Out connector at the rear of the unit). The parameters associated with this action are
identical to the BNC Output action described above, with the addition that since there are
two outputs on the breakout board, there is an additional parameter of "Trigger
Destination" with the allowed values of "Output 0" or Output 1".